zoom_in
fuji_fkc_1
Sale

Fuji
Differential Pressure Transmitter
FKC Series
Range 13..1300mbar

869.05 Excl. VAT

Fuji/HART©, Input Range: 13…1.300 mbar, Output: 4-20mA,
Accuracy : 0,1%, Power Supply : 10,5…45 Vdc, Protection : IP67, Process Connection : 1/4”

Product Attachment : PDF

Available on backorder

Description

The FKC differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge
pressure or flow rate and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micromachined
capacitance silicon sensor with state-of-the-art microprocessor technology to provide exceptional performance and
functionality.

FEATURES of FKC Series

1. High accuracy up to ±0.04%
0.065% accuracy as standard, 0.04% accuracy as option. Fuji’s micro-capacitance silicon sensor assures this accuracy
for all elevated or suppressed calibration ranges without additional adjustment.

2. Minimum environmental influence
The “Advanced Floating Cell” design which protects the pressure sensor against changes in temperature, static pressure,
and overpressure substantially reduces total measurement error in actual field applications.

3. Fuji/HART® bilingual communications protocol
FCX–AII series transmitter offers bilingual communications to speak both Fuji proprietary protocol and HART®. Any
HART® compatible devices can communicate with FCX-AII

4. Application flexibility
Various options that render the FCX–AII suitable for almost any process applications include.
– Full range of hazardous area approvals
– Built-in RFI filter and lightning arrester
– 5-digit LCD meter with engineering unit
– Stainless steel electronics housing
– Wide selection of materials

5. Programmable output Linearization Function
In addition to Linear and Square Root, output signal can be freely programmable. (Up to 14 compensated points at approximation.)

6. Burnout current flexibility (Under Scale: 3.2 to 4.0mA,
Over Scale: 20.0 to 22.5mA) Burnout signal level is adjustable using Model FXW or Hand Held Communicator (HHC)
to comply with NAMUR NE43.

7. Dry calibration without reference pressure
Thanks to the best combination of unique construction of mechanical parts (Sensor unit) and high performance electronics
circuit (Electronics unit), reliability of dry calibration without reference pressure is at equal level as wet calibration.

Additional Information
Weight 3.60 kg
Dimensions 40 × 30 × 30 cm
Fuji Electric

Type

Input Range (mbar)

Power Supply

Output

Maker

Price €

Brand

Fuji Electric